Honeywell Thermopile Voltage Low: How to Fix It?

Honeywell Thermopile Voltage Low – In the beginning, you need to be aware of what the thermopile actually is. It’s an electronic device that converts the energy of heat into electrical electricity. It also contains thermocouples, either in parallel or in series configurations.

The thermocouples work through the measurement of temperature difference at the junction point in which it was measured. thermocouple’s output voltage was measured.

As we’ve mentioned, the device can convert the energy of thermal radiation into electrical energy. It is no wonder it is also utilized for water heaters. the heating element of the water. There are times when people inquire about the thermopile voltage being low on a heater for the water.

It is important to understand that the pilot light will warm the thermocouple and thermopile that produce tiny millivolts of electricity that travel into the valve for gas controls. It is important to know that the currents from the thermocouple regulate the pillow tube inside the hollow copper, with the wires within.

The electricity is generated through two cables which pass the tco, and then go into the control for gas. If you observe that the light is not working, the lower power supply causes the shutdown of all gas that is connected to the water heater. The normal function will resume after when the lighting on the pilot comes back on.

The older model of the water heater needs some adjustment and patience in order to ignite the pilot. However, the modern water heaters have sealed off the combustion area and used the spark created by the device specially designed to light your pilot again.

Thermopile Voltage Low On Water Heater

As we mentioned earlier, an instrument can generate the spark that relights the pilot flame. This pilot’s flame can be lit by the blue flame once the water heater is supplied with adequate gas pressure.

The pilot lights do some tasks, such as heating the thermocouple, or thermopile. This creates tiny electrical current that is used to power the gas control system. It sends the necessary signals to the valve for gas control that the pilot was switched on and then turned off the gas as it shut down.

It is important to know what a thermopile one or more thermocouples that have been joined together. The thermopile could cause higher currents, but not as much as thermocouples. The thermopile produces enough currents to power the circuit board in the electronic gas. It can also cause problems with the state of operation of your heater and release error codes via the led status and control of the operation.

Thermocouples also generate a tiny electrical current for the gas valve mechanically however, it does not provide enough current for the circuit board in the electronic gas control.

Honeywell Thermopile Voltage Low Fix

Open the thermopile’s open circuit for to conduct a test

Follow the instructions for lighting on the water heater. After that, you are able to switch on the pilot and allow it to run for about three minutes.

If your pilot has no light, you need to keep the control button on the pilot and turn the knob that controls gas to the pilot’s position and then push and hold in place in order to complete this procedure during the test.

It is possible to use a multimeter that can measure millivolts. Place an end of the harness on left and place the second lead on the opposite side. If the multimeter is reading 300 millivolts or higher, the thermophile is fine. However, if it reads less than 300 millivolts, you must replace the pillow right away.

Test the thermophile test in closed circuits

You must remove the white and red cable for the pilot from gas controls. It is possible to use a multimeter, which measures the millivolt. Connect two leads to red wire, and the other cable to the white wire. Follow the lighting directions on the heater, and then switch the ignition on and let the heater run for approximately three minutes.

It is important to hold the knob for your gas control to the point of the control. Rerun this test. If it is reading more than 400 millivolts, it is a good thermophile reading for the device you are using. If the reading is lower than 400 millivolts then you have a an insufficient thermopile.

Thermopile Voltage Low Rheem

The water heater might not be working as expected, and your gas valve blinks with two lights, meaning you have a the voltage thermopile. Numerous sources inform you of the thermopile voltage being low on your water heater.

To give an example, check out the video below regarding Water Heater Pilot Light & Thermopile Troubleshooting: